HS-100FRT Accelerometer with Pt100 output for low speed applications
Vibration Monitoring with Hansford Sensors
Range of AC 100mV/g accelerometers is designed for use with all types of data collectors and online systems using two-wire constant current method of drive. The range includes standard, high performance premium and OEM accelerometers, each manufactured to the highest ISO standards and backed by our outstanding technical customer support services.
Key Features:
[no_unordered_list style=”circle” number_type=”circle_number” animate=”yes” font_weight=”normal”]
- Temperature (Pt100) and vibration outputs
- Sealed to IP68
- Various mountings
- Includes 5 metres of cable (other lengths available on request)
[/no_unordered_list]
Typical Applications:
Fans, pumps, motors, gearboxes, compressore, centrifuges, conveyors, Air handlers, rolls, dryers, presses, cooling, VAC, spindles, machine tooling, process equipment
Technical Performance |
---|
Mounted Base Resonance: see ‘How To Order’ table |
Sensitivity: see: ‘How To Order’ table ± 10% Nominal 80Hz at 22°C |
Frequency Response: 1.5Hz (90cpm) to 10kHz (600kcpm) ± 5% |
0.5Hz (30cpm) to 12kHz (720kcpm) ± 10% |
0.2Hz (12cpm) to 15kHz (900kcpm) ± 3dB |
Isolation: Base isolated |
Range: see: ‘How To Order’ table |
Temperature output: Pt100 (100Ohms) |
Transverse Sensitivity: Less than 5% |
Mechanical |
---|
Case Material: Stainless Steel |
Sensing Element/Construction: PZT/Compression |
Mounting Torque: 8Nm |
Weight: 125gms (nominal) |
Maximum Cable Length: 1000 metres |
Standard Cable Length: 5 metres |
Screened Cable: PUR – lenght to be specified with order |
Mounting Threads: see: ‘How To Order’ table |
Submersible Depth: 100 metres max (10bar) |
Electrical |
---|
Electrical Noise: 0.1mg max |
Current Range: 0.5mA to 8mA |
Bias Voltage: 10 – 12 Volts DC |
Settling Time: 2 seconds |
Output Impedance: 200 Ohms max. |
Case Isolation: >108 Ohms at 500 Volts |
Environmental |
---|
Operating Temperature Range: -30 to 90°C |
Sealing: IP68 |
Maximum Shock: 5000g |
EMC: EN61326-1:2013 |
Typical Frequency Response (at 100mV/g):