HS-100I Intrinsically Safe Accelerometer – Standard Top – PUR Cable
Vibration Monitoring with Hansford Sensors
Range of AC 100mV/g accelerometers is designed for use with all types of data collectors and online systems using two-wire constant current method of drive. The range includes standard, high performance premium and OEM accelerometers, each manufactured to the highest ISO standards and backed by our outstanding technical customer support services.
Key Features:
[no_unordered_list style=”circle” number_type=”circle_number” animate=”yes” font_weight=”normal”]
- ATEX approved
- US/Canada Class I, II, III, Division 1 & 2 approved
- Various mountings
- Sealed to IP68
- Submerged up to 100 metres (10 bar)
- Includes 5 metres of cable (other lengths available on request)
- Zener barrier information (MTL *see product 7728+ on page 9 of datasheet)
- Zener barrier information (P&F)
- Galvanic isolator information (P&F)
- For fans, pumps, motors, gearboxes and more
- Maximum cable lengths
[/no_unordered_list]
Typical Applications:
Fans, pumps, motors, gearboxes, compressore, centrifuges, conveyors, Air handlers, rolls, dryers, presses, cooling, HVAC, spindles, machine tooling, process equipment
Technical Performance |
---|
Mounted Base Resonance: see ‘How To Order’ table |
Sensitivity: see: ‘How To Order’ table ± 10% Nominal 80Hz at 22°C |
Frequency Response: 2Hz (120cpm) to 10kHz (600kcpm) ± 5% |
1.5Hz (90cpm) to 12kHz (720kcpm) ± 10% |
0.8Hz (48cpm) to 15kHz (900kcpm) ± 3dB |
Isolation: Base isolated |
Range: see: ‘How To Order’ table |
Transverse Sensitivity: Less than 5% |
Mechanical |
---|
Case Material: Stainless Steel |
Sensing Element/Construction: PZT/Compression |
Mounting Torque: 8Nm |
Weight: 125gms (nominal) |
Screened Cable Assembly: see: www.hansfordsensors.com for options |
Connector: PUR |
Mounting Threads: see: ‘How To Order’ table |
Electrical |
---|
Electrical Noise: 0.1mg max |
Current Range: 0.5mA to 8mA |
Bias Voltage: 10 – 12 Volts DC |
Settling Time: 2 seconds |
Output Impedance: 200 Ohms max. |
Case Isolation: >108 Ohms at 500 Volts |
Environmental |
---|
Operating Temperature Range: see: attached certification details |
Sealing: IP68 |
Maximum Shock: 5000g |
EMC: EN61326-1:2013 |
Typical Frequency Response (at 100mV/g):
Certifications: